The Micro 5000 Spirometer is an entry level PFT system with the ability to expand to include one additional test application and uses PFS (preVent® flow sensor) technology.

Optional applications include:

  • Mouth pressures (PeMax- PIMax and Mean values)
  • Sniff Testing (SNIP)
  • Airways resistance by interruption (Rint)
  • Lung Compliance with Oesophageal catheter (Latex)
  • Flow Limitation by applying negative Expiratory Pressure (NEP)
  • Dosimeter for Bronchial Challenge (PROVO4) {not available in all markets}
  • Small, compact system for complete basic spirometry measurement, including Forced Vital Capacity, Slow Vital Capacity, Maximum Voluntary Ventilation and Minute Tidal Ventilation including bronchial provocation testing software.
  • Semi-disposable / reusable preVent flow sensor, flow measurement from 0 to 15 l/s.
  • Low cost of operation and low maintenance.
  • Integrated weather station (temperature, humidity and barometric pressure) for BTPS correction of the volume.
  • Expair software suite with complete operator and patient guide included.


The Micro 5000 can be combined with the following devices:

  • BodyBox plethysmograph
  • HypAir pulmonary function testing system
  • SpiroAir volumetric pulmonary function testing system
  • Ergocard CPX exercise testing system
  • FeNO+
  • Resmon PRO FULL V3 forced oscillation technique

Ideal to complete a PFT lab, one of the following options can be added to the spirometry measurement in the Micro 5000.

Bronchoprovocation and Special Resistance Testing:

  • Provo 4 Provocation System: automated, software controlled, accurate and safe bronchial provocation testing.
  • RINT: resistance measurement using flow interruption technique. Ideal for children.
  • NEP (negative expiratory pressure): alternative method to detect and quantify expiratory flow limitation, which does not require performance of forced expiratory efforts nor a body plethysmography test.

Respiratory Mechanics Testing:

  • MIP – MEP (maximum inspiratory and maximum expiratory pressure): indicator of respiratory muscle strength.
  • SNIP: maximal nasal inspiratory pressure using a nasal cannula. A non-invasive indicator of diaphragmatic muscle fatigue.
  • P0.1: inspiratory occlusion pressure at 0.1 seconds, for respiratory muscle drive evaluation.

Static and dynamic compliance and resistance: measured by intra-esophageal balloon catheters.

Test Modes (standard)

  • Spirometry: FVC, SVC, MVV
  • ABG: Arterial Blood Gas Entry

Additional Test Mode (optional)

  • Provo 4: Bronchial Provocation With Automated Nebulizer
  • Rint: Resistance By Flow Interruption
  • MIP/MEP: Maximal Inspiratory and Expiratory Pressure
  • SNIP: Spontaneous Nasal Inspiratory Pressure
  • P0.1: Inspiratory Occlusion Pressure at 0.1 Seconds
  • NEP: Negative Expiratory Pressure
  • Static and Dynamic Compliance

Software features (standard)

  • Bronchial Provocation Software
  • ATS/ERS Criteria Checklist
  • MySQL Database
  • Pediatric Incentives
  • Report Designer
  • Trend Reports
  • User-Defined Predicteds

Additional Software Features (optional)

  • PDF Report Exportation
  • Numerical Data Exportation (XLS, TXT, XML)
  • HL7 Interface Software

An Integrated System

Expair Cardiorespiratory Diagnostic Software
  • Intuitive and user-friendly interface
  • Choice of languages and units of measurement
  • Full calculation function, display of calculation points with manual correction capability
  • Quality control automated software, diagnostic functions and full program control
  • Predicted value editor, new interpretation algorithm based on LLN, ULN, Z-score and percentile.
  • Trend tabular data reporting of any parameter
  • Results export capabilities (PDF, TXT, XML) for research or integration to Hospital Information System
  • Report designer, comments and offline input


See Software Solutions

HL7 Interface Software

Our HL7 interface software allows any number of networked systems to exchange data with the electronic medical records (EMR) system.

  • Electronic medical record interface using latest HL7 standards with either unidirectional or bidirectional capability

Flexible access allows physicians to view and interpret patient results from any location on the facility’s network.

preVent® Flow Sensor for Simplicity and Accuracy

Our proprietary preVent® flow sensor saves time between patients and provides maximum infection control compared to other pneumotach devices.

  • Eliminates warm-up or flow recalibration between patients.
  • Simple snap in setup contains no moving parts or electronics for maximum infection control.
  • Options to use with a filter (for PFT), sterilize, or discard, making it extremely versatile and cost effective.
  • Meets ATS/ERS standards and specifications.

 